Search results for "Detection of harmonic sources"

showing 4 items of 4 documents

Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems

2008

This paper deals with an innovative technique for the detection of disturbing loads in distorted power systems. The technique is a single-point strategy based on a comparison among different ldquononactiverdquo power quantities already proposed in the literature, which are measured at the same metering section. In this paper, the effectiveness of the strategy is discussed, which also considered the errors of the measurement transducers; the analysis is supported by simulation tests, which were carried out on both a simple single-phase system and an IEEE standard three-phase test power system. The latter was used by other authors as a benchmark system for the analysis of multipoint measureme…

Total harmonic distortionEngineeringbusiness.industrySystem testingAC powerDetection of harmonic sources harmonic distortion power quality power system harmonics reactive powerPower (physics)Electric power systemPower system simulationHarmonicElectronic engineeringMetering modeElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationIEEE Transactions on Instrumentation and Measurement
researchProduct

Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers

2007

This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers.

Total harmonic distortionEngineeringbusiness.industryPower system harmonicsPower quality harmonic distortion reactive power power system harmonics detection of harmonic sources.AC powerPower (physics)Electric power systemTransducerHarmonic pollutionElectronic engineeringMetering modebusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000

2010

In this paper, a novel single-point strategy is proposed for the detection of the harmonic sources in power systems. The method is an improvement of a strategy previously proposed by the authors; it is developed from the IEEE Std 1459-2000 approach and it can be entirely implemented in the time domain, thus simplifying the measurement system. The effectiveness of the proposed method is evaluated by introducing simple decision-making rules and by taking the presence of the measurement transducers into account. Several simulations and experimental tests are presented, showing that the enhanced strategy is able to give an useful information on the detection of the dominant harmonic source upst…

EngineeringTotal harmonic distortionbusiness.industrySystem of measurementEnergy Engineering and Power TechnologyAC powerlaw.inventionElectric power systemlawElectrical networkHarmonicElectronic engineeringUpstream (networking)Time domainElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheDetection of harmonic sources harmonic distortion IEEE Std. 1459–2000 power definitions power measurement power quality (PQ)IEEE Transactions on Power Delivery
researchProduct

A novel approach based on nonactive powers for the identification of disturbing loads in power systems

2007

In this paper, a new approach is proposed for the detection of harmonic sources in polluted power systems. It is a single- point strategy, based on a comparison among different "nonactive" power quantities proposed in literature that, in the same working conditions, assume different values at the same metering section. Some simulations tests were carried out on a standard IEEE test system proposed by other authors as a benchmark system for the analysis of multipoint measurement techniques for harmonic pollution monitoring. The obtained results show that the proposed single-point approach is in agreement with other strategies already proposed in the literature and can provide useful indicati…

Total harmonic distortionEngineeringbusiness.industryEnergy Engineering and Power TechnologyAC powerDetection of harmonic sources harmonic distortion power quality power system harmonics reactive powerPower (physics)Harmonic analysisElectric power systemPower system simulationHarmonicElectronic engineeringMetering modeElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct